Description
DIN rail mounting protection relays for use in single and three phase systems. Available in 55mm x 112mm or 100 x 112mm DIN rail cases
Selection Guide
M200-F1U | Single or 3 phase under frequency |
M200-F1O | Single or 3 phase over frequency |
M200-F1C | Single or 3 phase combined under and over frequency |
Typical Applications
The M200 series frequency protection relays are designed to monitor the frequency of a system and if the frequency deviates outside the customer adjustable preset limits, the relay will operate. Typically used in protecting generators against under or over speed, this is achieved as speed is proportional to frequency.
Other uses such as monitoring mains power supplies, computer supplies etc. The user is provided with adjustment of both the trip point of frequency being monitored and the differential. As is common with all the M200 relays, on over units the relay energises when the input signal exceeds the trip point. A red LED indicates the state of the relay, whilst a green LED indicates the condition of the power supply. The frequency relays monitor their own power supply so no auxiliary power is required.
Technical Specifications
INPUT | |
Rated value Un | 57.8<500V ±25% |
Rated frequency | 50/60/400Hz |
Burden | < 2.5VA |
Overload | 1.5 x Un continuous 2 x Un for 3 seconds |
SETPOINT | |
Range 50Hz nominal | Adjustable 40 to 60Hz |
Range 60Hz nominal | Adjustable 50 to 70Hz |
Range 400Hz | Adjustable 360 to 440Hz |
Differential 50 & 60Hz | Adjustable 0.3 to 3Hz |
Differential 400Hz | Adjustable 3 to 30Hz |
Repeatability | Better than 0.5% of full span |
Operating Time | Typically 200ms |
AUXILIARY | All units self powered |
WEIGHT&CASE | |
Single units | Approx 0.4kg. 55mm case |
Combined Units | Approx 0.6kg. 100mm case |
Options
1 | On all of the above units an internally set time delay is available for any value between 1 & 10 seconds. To order use the above codes adding a D at the end of the code. e.g M200-F1U / D7 seconds (state the fixed delay period). |
2 | AC auxiliary in range 57.7 to 480 volts |
3 | To prevent nuisance tripping when there is a slight variation in the frequency the following option is available. The external differential is replaced with an external time delay. On these units the time delay is adjustable from 200mS to 10 second, and the differential is fixed at 1%. |
M200-F1X: Single or 3 phase under frequency | |
M200-F1Y: Single or 3 phase over frequency | |
M200-F1W: Single or 3 phase combined frequency | |
4 | Calibration at temperature other than 23ºC |
Connection Diagrams