Description
DIN Rail mounting multifunction transducers supplied in 100 x 112mm DIN rail cases.
The M560 PowerSig is a complete 1 phase or 3 phase multifunction AC power transducer with 3 analogue outputs
Application
Self contained measurement of a wide range of electrical paremeters, where communication options are required
Analogue Outputs
Upto 3 fully isolated outputs are available. Most of the parameters measured can be assigned to the outputs. Outputs can be either DC mA or DC volts. If PowerSig is purchased without the option of RS485 the user must specify which parameter is required for each output when ordering.
Options
RS485 Output – This is auto configurable and set up software is provided.
Pulsed Output – This can be assigned to Wh, Varh, Ah or Vah
ModelDetails
M560-AT1: Single Phase
M560-AT1-3:Single Phase 3 wire
M560-AT4: 3 Phase 3 wire Unbalanced Load
M560-AT9: 3 Phase 4 wire Unbalanced Load
DC Auxiliary
If RS485 output is not required. The customer should specify which parameter is required for analogue outputs, CT ratios, VT ratios, pulse duration etc. These can be programmed by out factory before despatch.
Ordering Information
Information Required | Example |
Product Code | M560-AT9 |
Nominal Input Voltage | 230 L/N |
Nominal Input Current | 5A AC |
System Frequency | 50Hz |
Auxiliary | 230V AC |
Output | 3 x 4-20mA |
Option | RS485 Modbus |
Specifications
ACCURACY | INPUT |
Specified @ 23ºC 10%-Un 10%-ln | Rated Un: Direct connected voltages between 57.8 and 600V. Specify Nominal |
Paremeters unless stated: Class 0.3% to IEC 688 | Range: 2-120% Un |
Volts and Amps: Class 0.25% to IEC 688 | Overload 1.5 x Un cont. 4 x Un for 1 sec |
Frequency: Class: 0.1Hz o IEC 688 | Rated In: 1 or 5 Amp |
Power Factor: Class: 1.0% to IEC 688 | Range 2-120% In |
Active and Reactive Energy: 1% of reading IEC 1036 | Burden: 0.5VA per phase Volts & Amps |
Overload: 4 x In continous. 50 x In for 1 sec | |
Frequency 50/60Hz Nominal range 45/65Hz | |
ANALOGUE OUTPUTS | APPLIED STANDARDS |
3 Outputs: Programmable to any 3 parameters (Apart from energy measurements) | General: IEC688 BSEN60688, BS4889, IEC359. |
Rated value: Specified @ 20mA | EMC: |
0-1mA into < 10 kOhm load | Emmisions: BSEN50081/1 |
0-5mA into < 2 kOhm load | Immunity BSEN50082/2 |
0-10mA into < 1 kOhm load | Safety: IEC 1010, BSEN601010 |
0-20mA into < 0.5 kOhm load | |
4-20mA into < 0.5 kOhm load | |
0-10 volts > 1 kOhm load | |
INSULATION | |
Test voltage: | 4kV RMS 50 Hz for 1 min |
Inputs / Case / Auxiliary / Output | |
3kV RS485 / Outputs | |
1.5kV relay | |
1kV between Outputs | |
Impulse Test: | EMC 5kV transient coplies with IEC801/ EN55020 HF |
Surge Withstand: | IEC801/EN55020 Ansi C37.90A |
Interference: | EHF 2.5kV 1Mhz complying to IEC255-4 |
Protective class II: | Complying to IEC348 |
ENVIRONMENT | APPROVALS |
Working temp: 0 – +60ºC | UL C-UL CSA |
Storage temp: -30 – 65ºC | |
Temp coefficient: 0.01% per ºC | |
AUXILIARY | |
AC voltage 115 or 230 or 277 volts (± 15%) | |
DC voltage 12 / 24 / 48 / 110 / 125 volts (± 15%) |